First, why most systems switch off
When the street loses power, your solar inverter (the box that turns solar power into household electricity) is built to stop. This is a safety rule. If it kept sending power out, it could put electricity onto cables that engineers believe are dead.
So a standard system, battery included, goes quiet when the grid does. That is not a fault. It is doing what it was designed to do.
Two ways a system can keep some power on
A few systems are set up to carry on. There are two common ways.
A backup socket (sometimes called EPS or UPS)
EPS stands for emergency power supply. UPS stands for uninterruptible power supply. The inverter has a second output that feeds one circuit or one socket. In a power cut that output can run a fridge, a router and a lamp. It usually does not run the whole house. An electrician has to wire it in.
Whole-house backup through a gateway
A gateway is a separate box that disconnects your home from the street and lets the battery supply your own wiring. It can keep most of the house running. It needs an electrician to fit, either at installation or later.
Neither
If your installer did not fit either one, your system will switch off in a power cut, even with a battery. Many homes are in this group. It is worth finding out which group you are in before the next cut.
Even with backup, some batteries need a nudge
If the system has switched off, or the battery has run flat, can it start again without the grid or the sun? Starting up from the battery alone is called a black start. Some batteries can do it, usually with a button on the battery. Some cannot.
The table below lists only the models where we could read the maker's own document. Where we could not, it says so. Please check your own manual. Model numbers matter, so a different model from the same brand may not work the same way.
| Brand and model | What the maker's document says | Source |
| FoxESS EP battery (EP3, EP4, EP5, EP10, EP11) | Has a Black Start function for when both solar and grid power are out. The steps use the battery's power switch and are in section 8.4 of the manual. The manual adds that wiring must not be changed during black start. | FoxESS EP battery manual V1.0.6 |
| Huawei LUNA2000-(5-30)-S0 battery | Has a black start button on the battery. If the battery has dropped to 0%, the button cannot start it. It can then be started only once both its DC and AC power supplies are connected. We did not confirm whether the backup output works with the grid down. That depends on how your system was installed. | LUNA2000-(5-30)-S0 user manual, Issue 17 (a distributor's copy of Huawei's manual) |
| SolaX HS2.5 and HS3.6 battery system | Has a black start. SolaX's guide says to press and hold the POWER button for 20 seconds or more. SolaX says the inverter and battery can then keep running when the grid and solar are not available. | SolaX black start guide |
| Solis hybrid (S6-EH1P-L-EU) | Not confirmed. The UK manual says the inverter can be powered on by solar only, battery only or grid only. That is about switching on, and we found no clear backup restart steps. Check your manual. | Solis S6-EH1P-L-EU manual V1.0 |
| GivEnergy, Sunsynk, Deye, Growatt, SolarEdge, Sigenergy, Tesla Powerwall, Enphase and others | Not confirmed. We did not find a clear black start procedure in the maker's documents that we could read. That does not mean they cannot do it. Check your manual, or ask the maker or your installer. | None |
Keep it simple. If your system stops and will not restart, do not open the unit or touch the wiring. Follow the button steps in your own manual only if you are sure they match your model. Otherwise call your installer or the maker.
A simple checklist
- Read the make and model from the labels on your inverter and battery. Write them down. Do not open anything.
- Look in the manual, or on the maker's website, for the words "EPS", "UPS", "backup", "emergency power" and "black start".
- Ask your installer whether backup was fitted. If so, ask which sockets or circuits it covers.
- Ask whether your battery keeps a reserve for power cuts, and how much. A battery that has run flat may not restart on its own.
- Ask your installer to show you how to test backup safely. Do not test it yourself by switching off your main supply.
- Print the black start steps for your model, if it has them. Keep the page near the unit.
- Keep a torch and a charged phone to hand. Do not rely on the battery for everything.
During a power cut
Phone 105. It is free, and it connects you to your local network operator (the company that looks after the cables in your area). The 105 website is run by the Energy Networks Association for the network operators in Great Britain. Visit powercut105.com.
What to ask your installer
- Is my system set up to work in a power cut? Which circuits does it cover?
- Is it a backup socket, or whole-house backup through a gateway?
- How long will the battery run the things I care about, such as the fridge, the router and any medical equipment?
- If the battery runs flat, can it restart on its own? What are the exact steps for my model?
- If I wanted backup added, what would it involve and cost?
Sources